Pressure Rating
The following is the maximum recommended working pressures of Corflex Pinch Valves and test pressures.
Sleeve failure is in excess of three times the maximum recommended working pressure.
Corflex Pinch Valve Maximum Recommended Working Pressure - Bar
| Size mm (dia) | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
| Standard Valve | 40 | 33 | 25 | 20 | 22 | 18 | 15 | 14 | 12 | 10 | 9 |
| Heavy Duty Valve | 78 | 66 | 43 | 29 | 37 | 30 | 26 | 23 | 20 | 18 | 16 |
| Extra Heavy Duty Valve | 200 | 175 | 143 | 120 | 72 | 59 | 50 | 44 | 39 | 35 | 32 |
Corflex Pinch Valve Sleeve Test Pressures - Bar
| Size mm (dia) | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
| Standard valve | 80 | 65 | 50 | 40 | 43 | 35 | 30 | 28 | 23 | 20 | 18 |
| Heavy duty valve | 156 | 112 | 86 | 57 | 73 | 59 | 51 | 45 | 40 | 35 | 32 |
| Extra heavy duty valve | 400 | 350 | 285 | 200 | 144 | 118 | 101 | 88 | 77 | 69 | 63 |